87F16 Furnace Primary Limit Switch up to 140°F - For Lennox Furnaces - Replaces 87F16 87F1601 L140-30F 36T01B387F16 Furnace Primary Limit Switch up to 140F Key Features Primary high limit safety control for forced air furnaces Activates at a fixed temperature of 140F (60C) to prevent overheating Automatically resets at 110F (43C) Switch configuration: SPST (Single Pole, Single Throw), normally open contacts Probe insertion length: 3 inches Replaces Cross Reference Part Numbers 87F16 87F1601 L140 30F L140F 40 36T01B3 42155 A1247 Compatibility & Fitment
87F16 Furnace Primary Limit Switch up to 140°F
Key Features
- Primary high-limit safety control for forced-air furnaces
- Activates at a fixed temperature of 140°F (60°C) to prevent overheating
- Automatically resets at 110°F (43°C)
- Switch configuration: SPST (Single Pole, Single Throw), normally open contacts
- Probe insertion length: 3 inches
Replaces / Cross-Reference Part Numbers
- 87F16
- 87F1601
- L140-30F
- L140F-40
- 36T01B3
- 42155
- A1247
Compatibility & Fitment
- Designed as a direct replacement for specific Lennox brand furnaces.
- Verify fitment by confirming the part number on your original switch or in your equipment's service manual.
When to Replace
- Furnace blower runs continuously after the heating cycle has stopped.
- Heating system short-cycles or shuts down prematurely.
- Furnace fails to produce heat or ignite the burners.
- Control board displays a fault code indicating an open limit switch.
Installation Tips
- Disconnect all electrical power to the furnace before servicing.
- Locate the limit switch, typically mounted on the furnace plenum near the heat exchanger.
- Note wire connections before removing the old switch.
- Install the new switch, secure it with the mounting screws, and reconnect the wires to the terminals.
- Restore power and test the furnace through a complete heating cycle to ensure proper operation.
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy